Operating Manual - 24.24M Matrix Processor
8
6. EXPANSION MODULE INSTALLATION
The Ashly 24.24M can be ordered from the factory with expansion modules pre-installed to suit the application, or
as a 4 x 4 base unit. Should the need arise to add input or output capacity at a later time, additional four channel input
or output modules can be purchased and easily installed in the field.
There are a total of four expansion slots available, and each slot accepts either an input or an output module. The
24.24M as well as Protea System Software autodetect if a slot has been filled, and whether it is an input or output. The
software interface automatically updates to reflect the current 24.24M expansion slot configuration.
Please note that while field installation is not complicated, there is a risk of ESD (electrostatic discharge) damage
to circuit board components if the board is improperly handled.
To install an additional expansion module, refer the following procedure to a qualified service technician:
1.) Remove AC power cord from back of unit and place unit on grounded work surface.
2.) Remove the seven top cover screws and remove cover. Remove expansion slot covers from back panel.
3.) Discharge any personal static by touching a grounded object. Carefully remove the new expansion card and
flat cable from the ESD protective bag.
4.) Follow the instructions in the above drawing for installing expansion modules. Ashly recommends placing
input expansion modules starting with EXP1, and placing output expansion modules starting from EXP 4 and working
backwards. This way input and output channels are continuously numbered up from channel 1.
6.) In some cases it may be necessary to remove an existing expansion card before installing an new adjacent one.
Certain motherboard flatcable headers may be inaccessible with modules installed above them.
7.) Make sure all hardware is secure, then replace top cover.
For further information on expansion module assembly or proper ESD protection, please contact the Ashly service
department at 1-800-828-6308.
Expansion Card #1
Inputs 5-8
Outputs 17-20
Expansion Card #2
Inputs 9-12
Outputs 13-16
Expansion Card #3
Input 13-16
Outputs 9-12
Expansion Card #4
Inputs 17-20
Outputs 5-8
Expansion Card Assembly:
*See ESD Precautions First
1.) Plug ribbon cable into
motherboard header
2.) Plug other end of ribbon
cable into expansion slot
3.) Slide pcb fingers into
slots on back of meter card
4.) Fit Euroblock connectors
through back panel cut-outs
5.) Fasten two back panel
screws
EXP1EXP2EXP3EXP4
Flatcable(s)
to
Motherboard
12
3
4
5
5